A counterattack crusher can also be called a counterattack breaker. The impact crusher can process materials with a side length of 100-500mm or less, and has the characteristic of high compressive strength, which can reach up to 350MPa. The impact crusher has the advantages of large crushing ratio, high output, and cubic particle shape after crushing. However, it has to be said that the working environment for counterattacks is quite harsh, and after a long period of operation, malfunctions are inevitable. As long as the machine malfunctions and stops, it will directly delay the construction period of the quarry, causing significant losses and high maintenance costs. But if you have a good understanding of common faults in counterattacks, you can quickly find the cause and solution of the fault, quickly restore normal production, and reduce losses. Here are some common faults and repair methods summarized by the editor for everyone! 1、 The bearing of the impact crusher heats up: it is necessary to regularly check whether the lubrication of the bearing is good. Under normal circumstances, the lubricating oil should fill 50% of the bearing seat volume; Another situation is that the lubricating oil has deteriorated and become viscous, requiring cleaning of the bearings and replacement with new lubricating oil. 2、 Abnormal vibration of the equipment: there is a high possibility of excessive feeding size; The wear of wear-resistant parts is uneven, and the impact hammer needs to be replaced; The rotor is unbalanced and needs to be adjusted and balanced; Check if the anchor bolts of the equipment are tightened and reinforce them appropriately.
3、 If the particle size of the discharged material is too large, it indicates that the hammer or lining plate of the impact crusher is severely worn, causing the gap between the hammer and the impact plate to be too large. Adjust the gap between the front and rear impact frames, or replace the lining plate and hammer; Adjust the position of the counterattack frame so that the gap between the two sides and the frame lining plate is uniform; If the lining plate on the rack is severely worn, it should be replaced in a timely manner. 4、 During the operation of the equipment, if there is a rubber smell and the belt slips, causing friction and heating with the pulley and emitting a pungent rubber smell, or if the rotor is stuck, it is necessary to check the condition of the rotor inside the machine cavity and solve it in a timely manner.
5、 The main reason for the reversal of the counterattack broken belt is due to belt damage, and the triangular belt needs to be replaced to ensure the quality of the belt; Or due to improper assembly of the pulley, it is necessary to adjust the driving and driven pulleys on the same plane. It is necessary to understand the operation of the equipment in advance, proficiently operate it, think of possible faults, and quickly identify the cause and solve problems in a timely manner, which can effectively avoid major losses caused by downtime due to faults.